Ag-leader Versa DirectCommand OPTRX Quick Reference Guides Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Ag-leader Versa DirectCommand OPTRX Quick Reference Guides. Ag Leader Versa DirectCommand OPTRX Quick Reference Guides User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 4
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
DirectCommand
TM
OptRx
Quick Reference Guide
2006312 - ENG Rev C
The Sensor Conguration button
takes user to the Sensor Setup
screen.
Sensor Setup screen
The status of each sensor is shown“ON” or “OFF”.
Crop Sensors can be enabled or disabled from this
screen.
Create Conguration
Enter Settings
Start of Conguration Wizard
Corn,
North American Wheat,
and Europe settings
are discussed on
the next page
Application
Conguration
Product
Application
Press to Highlight Conguration
4930rx
Sensor
Conguration
Corn
Settings
North America
Wheat
Settings
Europe
Settings
Serial Number:
Firmware Version:
Hardware Revision:
2006930001
127.127.127.127
Unknown
Crop sensor technology designed by Holland Scientic Inc.
Crop Sensor
The table can have 2-16 ranges. Each Range is dened by a lower and upper
bound and a rate to apply. The bounds and rate can be changed using the
numeric pad. Operator can choose VI Type (NDVI or NDRE).
To activated Application Rate Table
To input values in to the Application Rate Table
Application Rate Table
Rate
Table
Crop
Sensor
Sensor
Conguration
Corn
Settings
North American
Wheat
Settings
Europe
Settings
Crop
Sensor
Use Application
Rate Table
Your Conguration
Sensor Setup
Sensor Status
1 ON
2 ON
3 ON
4 ON
5 ON
6 ON
7 ON
8 N/A
9 N/A
10 N/A
Enable
Disable
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - DirectCommand

1DirectCommandTM OptRxQuick Reference Guide2006312 - ENG Rev CThe Sensor Conguration button takes user to the Sensor Setup screen.Sensor Setup screen

Strona 2

2DirectCommandTM OptRxQuick Reference Guide2006312 - ENG Rev C Corn SetupMinimum Rate - lowest amount of nitrogen operator wants appli

Strona 3

3DirectCommandTM OptRxQuick Reference Guide2006312 - ENG Rev CRun Screen.V.I. Reference ValueYou must scan a portion of the eld and create a V.I. Ref

Strona 4

4DirectCommandTM OptRxQuick Reference Guide2006312 - ENG Rev CPress the OptRx prescription rate button in the Product Control Toolbox to engage the Op

Komentarze do niniejszej Instrukcji

Brak uwag