* Valve On Latency − the time that it takes for the system to begin spraying after you turn it on.
* Valve Off Latency − the time that it takes for the system to stop spraying after you turn it off.
Tip: To calculate the latency values, time your system with a stopwatch
Intentional
Overlap
Allows you to double−spray (buffer) a set distance to ensure complete coverage and avoid skips.
There are two settings, measured in distance:
* On Overlap Distance − the overlap buffer when travelling into an area to be sprayed from an
already sprayed area. Spraying begins this distance before the area to be sprayed.
* Off Overlap Distance − the overlap buffer when leaving the area just sprayed and entering an
already sprayed area. Spraying stops this distance outside the area just sprayed.
Manual override
To manually override automatic boom switching, for example to double−spray or spray in corners, you must
change the Boom Control option to Manual.