Alternatively, connect the Hardi 5500 variable rate controller to the EZ−Guide 500 lightbar AUX port as shown
below.
ITEM DESCRIPTION
1 EZ−Guide 500 lightbar
2 Ag15 antenna
3 Antenna cable (PN 50449)
4 EZ−Guide 500 power cable (PN 62817)
5 To power
6 EZ−Guide 500 AUX port cable (PN 62609)
7 Serial port extender (PN 63076)
8 Hardi 5500 (COM1) to EZ−Guide 500 cable (PN 59043)
9 Hardi 5500 Controller
Note: The Hardi 5500 controller must have firmware version 3.16 or greater installed and have a JOBCOM
control box connected for it to work correctly with the EZ−Guide 500 lightbar.
EZ−Guide 500 to Hardi controller cable pinouts
The pinouts for the EZ−Guide 500 to Raven controller cable (PN 59043) is shown below: